Please login to use this feature. You can use this feature to favourite your items and stores.
Close
You have added this item to your favorite list. View My Favorite List
Close
You have removed this item from your favourite list.
Close
Please login to use this feature. You can use this feature to favourite your items and stores.
Close
You have added this shop to your favourite list. View My Favourite List
Close
You have removed this shop from your favourite list.
Close
Muser Apac Sdn Bhd
Muser Apac Sdn Bhd (716179-D)
Muser Apac Sdn Bhd (716179-D)
(0) 0 out of 5 stars See Shop Review (0)

sales@muser-testo.com.my
+603-2742 7468

Region: Kuala Lumpur (KL), Malaysia, Selangor

Shop Information Newpages Premium Profile
3Visitor 7Orders
136
Active Products

Click the favourite shop button beside of the banner, when discount coupon is created you will see at the member panel > discount coupon page.

Testo 310 - Entry-Level Flue Gas Analyzer [Delivery: 3-5 days subject to availability]

RM2934.00

Weight: - kg

  • Out of Stock
    We're sorry! This product is not for sale now.
0 in stock
  • Product Details
    testo 310 - Entry-Level Flue Gas Analyzer
    Order-Nr.  0563 3100
     
    • Direct O2, CO, flue gas and ambient temperature measurements
    • Integrated measurement menu for flue gas, draft, CO ambient air and pressure
    • Quick sensor zero in only 30 seconds
    • Large, backlit digital display, rechargeable lithium battery with up to 10 hours life
    Being a systems mechanic you know only too well how tough things can get when you’re working out in the field. That’s why your measuring tools need to be rugged and reliable. Like the testo 310 flue gas analyzer. Designed especially for use in the field.
     
     
    Product Description
     
    Accurate readings, rugged design, easy-to-use: That’s what you as a professional want from a measurement tool so that you can carry out quick and reliable checks on heating systems. And that’s exactly what you get with the testo 310 flue gas analyzer.
     

    The testo 310 entry-level flue gas analyzer. For reliable heating system checks
     
    The testo 310 has an easy-to-use menu guide, four integrated menus for flue gas, draft, CO ambient air and pressure measurements, a large, easy-to-read display and a backlight for use in all lighting conditions.

    But that is by no means all. The compact flue gas analyzer has a wide range of useful features that make it the ideal companion for plumbing and heating fitters. Thanks to the built-in magnet, it can stick to almost any metal object, like a burner for example, leaving both hands free for other tasks. The sensor can be zeroed in as little as 30 seconds and the sensor filter is just as easy to replace. In addition to that, the device has a rugged design which protects it against impact and damage and an easy-to-empty condensate collection tank.

    To round things off, the readings can also be transferred directly to your testo turbo printer (optional) via the analyzer’s infrared interface, allowing you to print out on site.



    What’s included
     
    testo 310 flue gas analyzer, rechargeable battery, calibration certificate for O2, CO, hPa and °C measurements, 7 in. conical sensor, silicone tube for pressure measurements, 10x particle filters, case.
     
     
    Technical Data
     

    Temperature - TC Type K (NiCr-Ni)
    Measuring range -20 to +100 °C
    Accuracy ±1 °C
    Resolution 0.1 °C
    Reaction time < 50 s
    Temperature (ambient temperature)
    Temperature - TC Type J (Fe-CuNi)
    Measuring range 0 to +400 °C
    Accuracy ±1 °C (0 to +100 °C)
    ±1.5 % of mv (> 100 °C)
    Resolution 0.1 °C
    Reaction time < 50 s
    Temperature (flue gas)
    Flue gas O
    Measuring range 0 to 21 Vol.%
    Accuracy ±0.2 Vol.%
    Resolution 0.1 Vol.%
    Reaction time t₉₀ 30 s
     
    Flue gas Draught
    Measuring range -20 to +20 hPa
    Accuracy ±0.03 hPa (-3.00 to +3.00 hPa)
    ±1.5 % of mv (Remaining Range)
    Resolution 0.01 hPa
     
    Flue gas degree of effectivity, Eta (calculated)
    Measuring range 0 to 120 %
    Resolution 0.1 %
     
    Flue gas loss (calculated)
    Measuring range 0 to 99.9 %
    Resolution 0.1 %
     
    Flue gas CO calculation (calculated from O)
    Measuring range 0 to CO max (Display range)
    Accuracy ±0.2 Vol.%
    Resolution 0.1 Vol.%
    Reaction time t₉₀ < 40 s
     
    Pressure measurement
    Measuring range -40 to +40 hPa
    Accuracy ±0.5 hPa
    Resolution 0.1 hPa
     
    Flue gas CO (without H-compensation)
    Measuring range 0 to 4000 ppm
    Accuracy ±20 ppm (0 to 400 ppm)
    ±5 % of mv (401 to 2000 ppm)
    ±10 % of mv (2001 to 4000 ppm)
    Resolution 1 ppm
    Reaction time t₉₀ 60 s
     
    Ambient CO
    Measuring range 0 to 4000 ppm
    Accuracy ±20 ppm (0 to 400 ppm)
    ±5 % of mv (401 to 2000 ppm)
    ±10 % of mv (2001 to 4000 ppm)
    Resolution 1 ppm
    Reaction time 60 s
     
    General technical data
    Dimensions 201 x 83 x 44 mm
    Operating temperature -5 to +45 °C
    Warranty Instrument: 24 months; Gas sensors: 24 months; Thermocouple 12 months; rechargeable battery: 12 months; Probe: 24 months
    Display type LCD
    Display function Backlit 2-line display
    Power supply Battery: 1500 mAh, mains unit 5V/1A
    Storage temperature -20 to +50 °C
    Weight (with probe) Approx. 700 g
     
     
    Applications
     
    Draught measurement in the flue gas duct
     
    Draught measurement is actually a differential pressure measurement. This differential pressure occurs between two sub-areas as a result of a difference in temperature. This is turn generates a flow to compensate. In the case of flue gas systems, the difference in pressure is an indicator of the “chimney flue draught”. This is measured between the flue gas and ambient air at the measurement orifice at the core of the flue gas flow.
     
    To ensure the flue gases are safely transported through the chimney there must be a differential pressure (chimney flue draught) for boiler systems that work with low pressure.
     
    If the draught is permanently too high, the average flue gas temperature increases and therefore flue gas loss. The level of efficiency drops.
     
    If the draught is permanently too low, oxygen may be lacking during combustion, resulting in soot and carbon monoxide. This will also cause a drop in the level of efficiency.
     
    Ambient CO measurement in the heated environment
     
    Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon (oil, gas, and solid fuels, etc.). If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation. This is why it is necessary to regularly check CO emissions at the combustion points of heating systems, and places often frequented by people (in our case, where the combustion systems for hot water generation are), and in the surrounding areas.
     
    Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)
    The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:
     
    1. Ensuring the atmosphere is contaminated as little as possible by pollutants; and
    2. energy is used as efficiently as possible.
     
    Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded.
     
    Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.
     
    Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.
     
    Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)
     
    Standard readings taken during services of domestic heating systems include checking the gas pressure on the burners. This involves measuring the gas flow pressure and gas resting pressure. The flow pressure, also called supplied pressure, refers to the gas pressure of the flowing gas and resting pressure of the static gas. If the flow pressure for gas boilers is slightly outside the 18 to 25 mbar range, adjustments must not be made and the boiler must not be put into operation. If put into operation nonetheless, the burner will not be able to function properly, and explosions will occur when setting the flame and ultimately malfunctions; the burner will therefore fail and the heating system will shut down.
     
     
    Downloads
     
    Product Brochures

    Product brochure testo 310  (PDF, 609 kB)
     
    Manuals

    Instruction manual testo 310  (PDF, 2.0 MB)
    Short manual testo 310  (PDF, 583.4 kB)
     
  • Rating & Reviews of Testo 310 - Entry-Level Flue Gas Analyzer [Delivery: 3-5 days subject to availability]
    0 out of 5 stars
    Average Rating & Reviews (0)

  • Payment Methods

    Online Fund Transfer / Cash or Cheque Deposit / ATM

    Payment Options:
    • Online E-Banking fund transfer
    • Cash/Cheque deposit at bank branches
    • Cash deposit terminal
    • Cheque deposit machine
    • ATM
    Please bank in the purchased amount into the bank account listed below:

    Beneficiary: Muser Apac Sdn Bhd
    Bank: Public Bank Berhad
    Account No.: 39 848 699 36
    Swift Code: PBBEMYKL


    After payment made, you MUST send us the copy of payment slip by
    1. Email to sales@muser-testo.com.my or 
    2. Go to www.newstore.my/en/my_purchases.html then click the update payment button to update your payment information to us. For guest can go to www.newstore.my/en/order_status.html

    Please stated,
    Order No.:
    Bank:
    Account No.:
    Transaction Date:
    Transaction Amount:

    Note:
    Please allow 2 extra working days for order processing if your payment method is Bank Cheque or Interbank Fund Transfer. The Order will be cancelled without any notice if the payment process not completed within 7 working days.
    Shipping Option
    Shipping Charges
    • Peninsular Malaysia (RM15.00)
      Shipping Fees:

      RM15.00/ order

    • East Malaysia (RM20.00)
      Shipping Fees:

      RM20.00/ order


    • Self Collect (free)

      Please Collect at:

      Muser Apac Sdn Bhd
      V Office 2, VO2-03A-03A, Lingkaran SV, Sunway Velocity, Jalan Peel, 55100 Kuala Lumpur.
       
      Any inquiry please contact us +603-27427468

    Return Policy
  • Product Enquiry
Browse by : Home - All Deals - New Deals - Popular Deals - Shop List - Join NEWSTORE